A three-eighths-inch bent plate bears on the structural steel roof deck and supporting steel beam at the perimeter edge. The bent plate is secured with a one-quarter-inch fillet weld, continuous at each end with a four-to-twelve minimum spacing. The overhang extends a maximum of two feet with a minimum two-inch field-installed adjustment per architectural drawings.
BENT PL 3/8 NOTE 1 4-12 MINIMUM 1/4 8" CONT EA END NOTES: 1. REFER TO ARCH DWGS TO DETERMINE EDGE OF BENT PL LOCATION. FIELD INSTALL BENT PLATE AS REQUIRED MIN 2" NOTE 1 2'-0" MAX NOTE 2 BENT PL 3/8 NOTE 1 4-12 MINIMUM 1/4 8" CONT EA END NOTES: 1. REFER TO ARCH DWGS TO DETERMINE EDGE OF BENT PL LOCATION. FIELD INSTALL BENT PLATE AS REQUIRED MIN 2" NOTE 1 2'-0" MAX NOTE 2