A cast-in-place leveler pit is formed within concrete tilt-up or pre-cast wall panels with a floor sloping down one-half inch toward the front. Steel angles are placed at interior corners, leaving a one-quarter inch gap between angles that is left unwelded and with side angles stopping short of the back angles. A dock leveler is stitch welded to the rear pit steel angle. Sawn control joints are incorporated into the concrete slab. Actual pit dimensions must be verified prior to forming.
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.