This assembly features a tilt-up wall panel supported by a continuous wall footing. At panel-to-panel connection locations, a concrete pier is provided, reinforced with eight number seven vertical bars and number three ties spaced at twelve inches on center. The pier is set on a one-inch grout bed above the footing. The adjacent concrete slab and pourback slab are keyed into the wall panel assembly as specified per plan. Exterior pavement is indicated adjacent to the footing, with all specific dimensions and slab thicknesses referenced to the structural and civil plans.
Text on the drawing
A A CONCRETE SLAB BEYOND TILT-WALL, SEE PLAN CONCRETE POURBACK SLAB, SEE PLAN CONCRETE SLAB, SEE PLAN TILT WALL PANEL WALL FOOTNG, SEE PLAN GROUT BED 1" CONC PIER @ EACH PANEL TO PANEL CONNECTION LOCATION (8) #7 VERT W/ #3 TIES @ 12" O.C. SEE PLAN 1'-6" 1'-0" DETAIL BOOK REF. SHEET: S1.37A-S DATE: 03/15/2024 SECTION A-A PAVEMENT, SEE CIVIL
Members view this detail in full resolution, download the CAD files (SVG, PDF), and open any detail in the built-in CAD editor to edit and export DXF or DWG.