A concrete slab T-joint features a continuous number four reinforcing bar positioned with one inch clearance from the top of the slab and one inch clearance along the vertical joint interface. The reinforcing extends one foot six inches above and one foot six inches below the intersecting slab element. Dimensions indicate vertical spacing and clear cover requirements for the concrete reinforcement.