A sheet metal hood connects to an endpanel, secured with a stud weld to the flange of the hood in three places. A one-inch flange at the back wall interfaces with the endpanel assembly alongside a continuous caulk bead for sealing. The flange attaches to the wall using bolts or screws through one-quarter-inch through holes at three locations.
QUARTER ENDPANEL-ND-2 ATTACH FLANGE TO WALL WITH BOLTS OR SCREWS HOOD CAULK BEAD ENDPANEL STUD WELD TO FLANGE OF HOOD 1/4" THRU HOLES 3 PLACES @ BACK WALL 1" FLANGE STUD WELD TO FLANGE OF HOOD 3 PLACES SECTION VIEW - MODEL 6030AM-ND-2-PSP-F HOOD - #2 (38 (L)) HOOD - #3 (38 (R))