Slab penetrations and blockout cans must maintain a minimum distance of four inches from column corners. Cans placed directly adjacent to columns have a maximum diameter of one foot six inches or two feet three inches depending on location. Additional aligned cans are permitted in line with the primary can next to the column. Reinforcing around the cans must be installed per the corresponding structural detail.
(4") 100 (4") 100 KEEP 'CANS' BACK FROM COLUMN CORNERS 100 (4") MINIMUM MAXIMUM 450 (1' -6") DIA. OR 685 (2' - 3") DIA. 'CANS' NEXT TO COLUMN OTHER 'CANS' ARE PERMITTED IN LINE WITH 'CAN' NEXT TO COLUMN. SEE DETAIL FOR REINFORCING AROUND 'CANS'