An embed plate measuring one-half inch by fourteen inches by the slab thickness is anchored into the concrete slab edge with four half-inch diameter by six-inch welded head studs, supplemented by two additional number four top and bottom reinforcing bars forty-eight inches long totaling four bars. A separate concrete wall detail shows an embed plate measuring five-eighths by fourteen inches by one foot two inches with four half-inch diameter by six-inch welded head studs, supported by additional number four reinforcing bars forty-eight inches each way totaling four bars with a two-inch clearance.
ADDL (2) #4 T&B x 48" (4) TOTAL EMBED PL1/2x14 x SLAB THICKNESS W/ (4) 1/2"Øx6" WHS 1 1/2" TYP CONC SLAB PER PLAN TYP 2" T/SLAB PER PLAN 1 1/2" TYP ADDL REINF CONC WALL PER PLAN EMBED PL5/8x14x1'-2" W/ (4) 1/2"Ø x 6" WHS ADDL (2) #4 x 48" EW (4 TOTAL) PER PLAN 2" CLR