A built-up steel stair stringer is composed of four three-eighths-inch thick plates welded at the corners with complete joint penetration welds ground smooth at the surface. A one-quarter-inch tread plate with a bent leg up and down spans between three-quarter-inch vertical riser plates. A vertical plate connects the tread assembly to the built-up stringer section. The stringer features a two-foot-two-inch maximum cantilever with dimensions coordinated with architectural drawings.
A A SECTION A-A BUILT-UP STL STAIR STRINGER BUILT-UP STL STAIR STRINGER COMPOSED OF (4) 3/8" THICK PLS WELDED AT CORNERS. WELD TO BE COMPLETE JOINT PENETRATING W/ SURFACE GROUND SMOOTH 1/4" TREAD PL BYND W/ BENT LEG UP (3/4" LEG) 1/4" TREAD PL W/ BENT LEG DOWN (3/4" LEG) 9" MIN 9" MIN VERT RISER PL TREAD PL 3/4" VERT RISER PL TREAD PL TO VERT RISER PL, TYP 2'-2" MAX CANT (SEE ARCH) 1'-0" (SEE ARCH) 2'-0" VERT PL TO BUILT-UP SECTION, TYP SEE ARCH DWGS FOR STAIR GEOMETRY NOT NOTED