Cable rail attachments at end and intermediate supports anchor to a concrete slab and column or shear wall. A 1/2-inch diameter cable rail passes through a 1-inch diameter pipe sleeve typical, spaced evenly at 4 inches on center over a 3-foot 9-inch vertical span. Galvanized mechanical anchor posts secure to a galvanized embed plate cast into the concrete assembly. Caulk is applied around the cable where it enters the hollow structural section to prevent moisture from entering the wedge cavity typical.
GRID CONC BEAM PER PLAN COL BEYOND PER PLAN T/SLAB PER PLAN ELEVATION AT INTERMEDIATE SUPPORT B VERIFY W/ ARCH, TYP 3'-9" (11) EQ SPACES @ 4"OC, TYP CLR 5" COL BEYOND PER PLAN 1/2"Ø CABLE RAIL IN 1"Ø PIPE SLEEVE, TYP GRID T/SLAB PER PLAN CONC SLAB PER PLAN COL OR SHEAR WALL BEYOND PER PLAN COL OR SHEAR WALL BEYOND PER PLAN GALV EMBED PL GALV MC ANCHOR POST CONC SLAB PER PLAN PLAN PER PLAN PER ELEVATION AT END SUPPORT A CAULK AROUND CABLE WHERE IT ENTERS HSS TO PREVENT MOISTURE FROM ENTERING THE WEDGE CAVITY, TYP NOTE: