The steel beam connects to the steel column using a one-half-inch shear tab fastened with three seven-eighth-inch diameter bolts. Fifty KSI continuity plates match the greater beam flange thickness plus one-eighth of an inch. Complete joint penetration welds secure the plate sides typically. Where vertical offsets exceed the one-to-three slope, horizontal continuity plates align with both flanges. A cantilevered floor beam utilizes a similar shear tab connection with typical weld access holes.
CANTILEVERED FLR BM STL BM (3) 7/8"Ø BOLTS TYP 1/2" SHEAR TAB, TYP WELD ACCESS HOLE, TYP STL BM CJP, TYP 5/16 TYP TYPICAL VERTICAL OFFSET OF CONTINUITY PLATES AT COLUMN FLANGE TYPICAL VERTICAL OFFSET OF CONTINUITY PLATES AT COLUMN WEB STL BM STL BM 50 KSI CONTINUITY PL'S = GREATER BM FLANGE THICKNESS + 1/8" 50 KSI CONTINUITY PL'S = GREATER BM FLANGE THICKNESS + 1/8" STL BM STL BM STL COL STL FLANGE STL WEB WHERE OFFSET EXCEEDS THE 1:3 SLOPE, PROVIDE HORIZ CONTINUITY PLS TO ALIGN W/ BOTH FLANGES SLOPE CONTINUITY PL'S 1 3 MIN 1 S802 1 S802 1 S802 1 S802 1 3 MIN SLOPE CONTINUITY PL'S WHERE OFFSET EXCEEDS THE 1:3 SLOPE, PROVIDE HORIZ CONTINUITY PLS WHERE SHOWN CJP SIDES TYP CJP (3) SIDES TYP