A typical gravity hollow structural section steel column splice is located four feet above the finish floor. The connection utilizes a three-quarter-inch thick steel plate matching the column dimensions, welded with three-eighths-inch welds. Continuous steel beams are supported by steel columns with SCP-1 and SCP-2 connections, incorporating full-height stiffener plates or single plates on each side unless noted otherwise, secured with one-quarter-inch fillet welds.
SF602-A3 HSS SPLICE HSS COLUMN 3/4" THICK STEEL PLATE TO MATCH COLUMN DIMENSIONS HSS COLUMN 3/8 3/8 4'-0" ABOVE FINISH FLOOR STEEL BEAM SCP-2 FULL HEIGHT STIFFENER PLATE OR SINGLE PLATE EACH SIDE U.N.O. 1/4 1/4 2 1/4 2 CENTER ON COL STEEL BEAM (CONTINUOUS) 1/4 STEEL COLUMN TYP FLR-Beam to Column SCP-1