The connection between a concrete slab on grade, a mat foundation, and a reinforced concrete water tank wall. The slab on grade features extended reinforcing with minimum development length or hooked anchorage with standard hook dimensions. Wall reinforcing consists of number 5 vertical and horizontal bars at eight inches on center, supplemented by top U-bars matching the wall vertical reinforcing spaced at twelve inches on center. A control joint is provided at the slab intersection per contractor option. Level elevations are designated at Level B1 and Level B2.
LEVEL B1 -13' - 0" 5 LEVEL B2 -21' - 6" Lsb TYP WATER TANK SOG #5 @ 8" VEF #5 @ 8" HEF U-BAR TO MATCH WALL VERT REINF #5x6'-0" @ 12" OC LEVEL B2 -21' - 6" MAT FDN EXTD SOG REINF Ld MIN OR HOOK W/ Ldh, TYP SOG CJ AT CONTR OPT