A structural steel column base plate connects to a concrete slab on grade and grade beam with eight 1-3/4 inch diameter anchor rods. A 2-1/4 inch thick by 70 inch by 26 inch base plate supports the column and a pinned core brace featuring a gusset plate. A 2 inch thick by 8 inch deep full width shear lug is welded beneath the base plate with a 7/16 inch fillet weld. The assembly integrates with a concrete slab on grade and sits over a concrete grade beam sized per plan.
SEE PLAN FF ELEV SEE PLAN TOF CONC SLAB ON GRADE, SEE PLAN CONC GRADE BEAM, SEE PLAN 1/4 2" THK x 8" DP x FULL WIDTH SHEAR LUG 7/16 5" 1'-8" 1'-8" 1'-8" 5" 3" 1'-8" 3" (8) 1 3/4" Ø ANC RODS, SEE DET --------. 5'-10" 2'-2" 2'-11" 2'-11" 1'-3" 4'-7" 2 1/4" x 70" x 26" BASE PL GRID WORK POINT 3/S-202 3" MIN 3" MIN GUSSET PL DESIGN BY 'CORE BRB' CNTR ON BEAM / COL 'CORE BRB' PINNED CONN BRACE 10" GRID DIAMOND BLOCK OUT, SEE DET ---------- 7/S-202 GRID BASE PLATE PLAN VIEW