A C8x channel connects to an HSS6x column using a top and bottom L2 1/2x1 1/2x1/4 angle welded with a three-sixteenths inch fillet weld. The channel web is welded to the column using a three-sixteenths inch fillet weld on both web sides. The top and bottom flanges feature a quarter-inch fillet weld at the T&B FLG connection. The angle leg is trimmed as required for a tight fit against the channel. Dimension callouts include seven and a half inches, four and a half inches, two inches, and a seven-eighths inch gap.
FOF .5A 7 1/2" 4 1/2" 2" 7/8" L2 1/2x1 1/2x1/4 (TRIM LEG AS REQUIRED FOR TIGHT FIT TO C8x) 3/16 3 SIDES SEAL SECTION A-A 1 S0.031 D SIM 3/16 C8x PER PLAN A A 3/16 3/16 WEB HSS6x PER PLAN 1/4 1/4 T&B FLG 3/16 T&B SEAL L2 1/2x1 1/2