A hollow structural section beam frames into an intersecting hollow structural section column with a two-inch clearance and a four-inch offset. A structural steel seat angle supports the bottom flange of the beam, sized as L4x4x3/8 by zero feet six inches for beam depths between four and six inches, and L6x6x3/8 by zero feet six inches for beam depths of six inches or greater. A shear tab connects the top flange of the beam to the column face. Quarter-inch fillet welds secure the connection assembly at the top and bottom flanges.
L4x4x3/8x0'-6" AT 4"< D < 6" L6x6x3/8x0'-6" AT D > 6" D HSS - SEE PLAN 2" CLR 4" HSS - SEE PLAN 1/4 1/4
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.