A continuous wide-flange beam bears upon a hollow structural section column with angle sections attached to each side. The structural angles feature 1-1/2-inch vertical short slot holes and are fastened with two 3/4-inch diameter ASTM A325 bolts positioned at the bottom of the vertical slots typically. A 3/16-inch fillet weld is applied on three sides as detailed per plan. Clearances include a 1-inch typical clearance and a 1/2-inch minimum typical dimension.
L8x4x1/2 AT EACH SIDE L8x4x1/2(LLV) TYP EA SIDE OF HSS W/(2) 1-1/2" VERT SHORT SLOT HOLES (2) 3/4"Ø A325 BOLTS AT BOTT OF VERT SLOT HOLES, TYP BEAM - SEE PLAN A-A A B A B B-B (AT OFFSET) BEAM SEE PLAN 3/16 3 SIDES SEE PLAN 1" CLR TYP 1/2" MIN 1 1/2" 1 1/2" 2" 1 1/2" 1 1/2"