This plumbing detail shows an inline pressure reducing valve assembly equipped with isolation valves typically positioned at both ends. A strainer precedes the pressure-reducing valve to capture upstream debris. Pressure gauges and Pete's plugs are installed on both sides to monitor operating pressures, accompanied by a thermometer for temperature measurement. A temperature and pressure safety valve rated for ninety pounds per square inch maximum is located downstream.
P/T PG PG P/T THERM PRESSURE GAUGE (TYP) PETES PLUG (TYP) STRAINER PRV ISOLATION VALVE (TYP) THERMOMETER T&P SAFETY VALVE 90 PSI MAX
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.