A vertical lap joint connection between tilt-up concrete walls utilizes a continuous steel angle sized per plan. A one-half-inch by twelve-inch by twenty-four-inch steel plate is positioned directly beneath the angles to distribute loads across the wall panels. A vertical lap dimension of two feet three inches accommodates the offset between the overlapping concrete panels.
2'-3" 1/2" x 12" x 24" PLATE PLACED UNDER ANGLES CONT. ANGLE PER PLAN . TILT-UP WALL
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.