A sprinkler head is installed adjacent to a concrete element with a minimum one-inch clearance above the finish grade. The associated trench contains a PVC lateral line and a PVC mainline bedded in two inches of sand or rock-free soil surrounded by compacted backfill, with five inches of topsoil in lawn areas. Tracer wires are taped to the side of the main line at ten-foot intervals. The layout maintains specific vertical depths and a two-inch horizontal separation between utility lines.
1" MIN 1" FINISH GRADE SPRINKLER HEAD CONCRETE PVC LATERAL LINE (18" DEEP FOR ROTOR AND IMPACT HEAD INSTALLATIONS) COMPACTED BACKFILL FINISH GRADE 5" DEEP TOPSOIL IN LAWN AREAS 2" SAND OR ROCK FREE SOIL AROUND ALL PIPE PVC MAINLINE TAPE WIRES TO SIDE OF MAIN LINE AT 10'-0" O.C. 12" 6" 2" HORIZONTAL SEPARATION