The drawing shows an end view and a plan view of a fence column base connected to a concrete footing and thickened slab. Key components include a 16-inch square concrete pedestal, a base plate welded to a hollow structural section column, hot-dip galvanized anchor bolts, non-shrink grout, and reinforcing bars such as #5 longitudinal bars and stirrups. The assembly provides structural support and anchorage for a fence post integrated into a slab-on-grade or foundation system.
Text on the drawing
PL 3/4x12"x1'-0" 3/16 3/16 3/16 FIN PL 1/2" FIN PLATE A-A PLAN VIEW AT EDGE PEDESTAL 16" 16" 4" 2" 2" OUTSIDE OF FENCE FENCED IN AREA 2" BASE PLATE MAY BE FLUSH TO OUTSIDE EDGE OF PEDESTAL 1" C L COL & PLATE A A MIN 4" 1-1/2" MAX NON-SHRINK GROUT BASE PLATE #3 STIRRUP AROUND ANCHOR BOLTS 2" FROM TOP OF PEDESTAL #5 HOOKED U-BAR AT EA END OF PEDESTAL 5/8" HDG ANCHOR BOLTS #5 @ 12" O.C. T&B LONG. TYP 3" CLR 16" SQ PEDESTAL TOE OF THICKENED SLAB EDGE NO CLOSER THAN EDGE EDGE OF PEDESTAL ABOVE AS SHOWN END VIEW EMBED 12" MIN 8" 6" 2" 2" C L HSS COL PER PLAN BASE PLATE W/ 1-1/2" MAX NON-SHRINK GROUT FTG & POST 4" 2" FENCED IN AREA OUTSIDE OF FENCE PL 3/4x12"x1'-0" PEDESTAL
Members view this detail in full resolution, download the CAD files (SVG, PDF), and open any detail in the built-in CAD editor to edit and export DXF or DWG.