A glulam beam connects to a collector via steel bucket plates positioned on each side of the timber member. The assembly is secured using either four or five three-quarter-inch through bolts, depending on the specific connection configuration. Slotted holes are provided in the upper portion of the bucket to accommodate movement, respecting a maximum distance to the bottom of the glulam beam. Shear plates of two and five-eighths inches are specified at all bolt locations on each side of the glulam beam for the five-bolt condition. A standard clearance of one-half inch is maintained to the top of the glulam beam, with specific spacing and edge distances detailed for the bolt group.
2 1/4" 1 3/4" BEAM 1/4" PLATE EA SIDE OF GLULAM BEAM PROVIDE SLOTTED HOLES IN BUCKET ABOVE MAXIMUM DISTANCE TO BOTTOM OF GLULAM BEAM AS SHOWN C L 1/2" TO TOP OF GLULAM BEAM (4) 3/4" THRU BOLTS 3 1/2" EQ EQ HOLES 10" MAX. FOR NON-SLOTTED 2 1/4" SPACING 3-1/2" MIN 1 3/4" EQ EQ EQ EQ BOLT GROUP, BEAM 1/4" PLATE EA SIDE OF GLULAM BEAM PROVIDE SLOTTED HOLES IN BUCKET ABOVE MAXIMUM DISTANCE TO BOTTOM OF GLULAM BEAM AS SHOWN C L C L 1/2" TO TOP OF GLULAM BEAM NON-SLOTTED 10" MAX FOR HOLES (5) 3/4" THRU BOLTS PROVIDE 2-5/8" SHEAR PLATES EA SIDE OF GLB AT ALL BOLTS