Cross-laminated timber panels meet at a vertical joint with a maximum gap of one-eighth inch, accommodating variable panel orientations. A Simpson CMSTC16 strap spans the panel joint and is secured with zero-point-one-four-eight-inch by two-and-a-half-inch nails spaced at three inches on center on each side.
3/4" STEEL PL. MATCH COL. SIZE OR 1/2" MIN. LARGER THAN STEEL COL. WHICHER 1/8" MAX PANEL GAP CLT PANEL, ORIENTATION MAY VARY SIMPSON CMSTC16 STRAP w/ 0.148" x 2.5" NAILS @ 3" O.C. EA SIDE
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.