Text on the drawing
FOR ADDITIONAL INFORMATION SEE 12 TOP FLANGE BOT FLANGE tbf WEB tbf * MIN 3/4" * * 6 1 2 3 4 5 4 1 3 1 BEVEL PER AWS. LARGER OF tbf OR 1/2" (+1/2 tbf, OR MINUS 1/4 tbf). 3/4 tbf TO tbf, 3/4" MINIMUM (+/- 1/4"). 3/8" MINIMUM RADIUS (+ NOT LIMITED, OR - 0). LARGER OF 3 tbf (+/- 1/2) OR 1-1/2". 0" @ COLUMN WEB, 5/8" @ COLUMN FLANGE. IF WEB CJP WELDS, USE 1/4" ROOT OPENING, 45° BEVEL. SURFACE ROUGHNESS AT BURNED SURFACES SHALL NOT EXCEED MICRO INCHES. GRINDING IS REQUIRED WHEN ≤500 MICRO INCHES. NOTE THIS COMES FROM AWS D1.8, AND ALSO MEETS AWS D1.1 AND AISC. DETAILER SHALL CONFIRM AISC MINIMUM EDGE DISTANCE BETWEEN HOLES AND WELD ACCESS HOLE IS MET. 2 3 4 5 6 7. 8. 9.