A six-inch steel pipe filled with concrete extends forty-two inches minimum above the top of the paving or floor surface and is painted safety yellow. The steel pipe is supported by a two-foot-diameter concrete footing with four number four bars welded to the pipe at its base. The assembly maintains the minimum code-required guard height of forty-two inches from the adjacent floor surface.
10" 4'-0" 4'-0" 1/2" 6" STEEL PIPE FILLED W/ CONCRETE - PAINT SAFETY YELLOW TOP OF PAVING OR FLOOR SURFACE 2' - 0" DIA CONCRETE FOOTING (4) #4 X 4" BARS WELDED TO PIPE 42" MIN 42" MIN NOTE: WHERE A GUARD IS REQUIRED BY THE BUILDING CODE, THE MINIMUM HEIGHT SHALL BE 42" (OR HIGHER IF SHOWN AS SUCH IN OTHER DETAILS) FROM THE FLOOR SURFACE IMMEDIATELY ADJACENT TO THE GUARD.