Accessibility clearances for swinging doors require specific approach dimensions on both the pull and push sides. The pull side requires a minimum sixty inch clearance perpendicular to the opening with a thirty six inch minimum clear width parallel to the door, or fifty four inches minimum with forty two inches respectively. The push side requires minimum dimensions designated as X and Y, where X is twelve inches minimum and Y is forty eight inches minimum when both a closer and latch are provided, and X is zero inches when neither is present.
(54" MIN) 60" MIN (OR 42" MIN AND...) 36" MIN PULL SIDE Y PUSH SIDE NOTE: X = 12" MIN AND Y = 48" MIN IF BOTH CLOSER AND LATCH ARE PROVIDED. X = 0" W/ NO CLOSER AND LATCH. D