The existing concrete wall surface is roughened to a quarter-inch amplitude before installing new shotcrete and reinforcing. Number four adhesive dowels are spaced at twelve inches on center with a twelve-inch minimum embedment depth and one and three-quarter inch clear cover typically. Number six adhesive dowels match the spacing of the wall horizontal reinforcing with a ten-inch minimum embedment. Hooked adhesive dowels provide additional anchorage per typical details.
ROUGHEN (E) SURFACE TO 1/4" AMPLITUDE (E) WALL #4 ADHESIVE DWLS. W/ STD. HK. 1 3/4" CLR. U.O.N. EMBED DEPTH 2" MIN. COVER TYP. (E) CONC. WALL s #4 ADHESIVE DOWELS @ 12" O.C., EMBED 12" MIN. PLAN HOOKED ADHESIVE DOWELS PER TYP DETAIL SHOTCRETE WALL AND REINF PER PLAN AND ELEVATION (E) CONC. WALL WALL REINF PER ELEVATION s CONCRETE WALL PER PLAN AND ELEVATION #6 AHD DOWELS TO MATCH SPACING OF WALL HORIZ REING. EMBED 10" MIN