At metal studs, attachments require two-and-a-quarter-inch-by-fourteen hex washer head Hilti screws complying with ESR 2196 driven through plywood into minimum 400S162-43 steel studs or sixteen gauge minimum backing. For attachment to concrete masonry units, use two half-inch Hilti KB3 expansion anchors through plywood into masonry with a three-and-a-half-inch minimum embedment installed per ICC-ES-1385. Standard washers measuring three-quarters of an inch in diameter by three-eighths of an inch thick minimum are required at fasteners where slotted holes occur. The maximum allowable load is two hundred sixty pounds with a four-foot-zero-inch spacing and a minimum distance of twelve inches to the point of attachment.
AT METAL STUD, PROVIDE 2-1/4"-14 WITH HEX WASHER HEAD HILTI SCREW (ESR 2196) THROUGH PLYWOODTO STEEL STUD (400S162-43 MIN) OR 16 GA MINIMUM BACKING 11/32" DIA. 1.7894 1.7894 .56 X 1.00 12" MIN. TO POINT OF ATTACHMENT MAX LOAD=260# OR 4'-0" SPACING. FOR ATTACHMENT TO CMU, USE (2)1/2" HILTI KB3 EXPANSION ANCHORS THROUGH PLYWOOD INTO CMU WITH 3-1/2" MINIMUM EMBED. INSTALL PER ICC-ES-1385. PROVIDE STANDARD WASHER (3/4" DIA. x3/8" THICK MINIMUM) AT FASTENER WHERE SLOTTED HOLE OCCURS.