Automatic door operators and access control devices are connected via three-quarter-inch conduits running to eight-by-eight-by-six-inch square junction boxes mounted in the ceiling space on the secure side of the doors. Surface-mounted exterior keypads and push plates route wiring through three-quarter-inch conduits to the ceiling junction boxes. Vestibule push plates and keypads similarly tie into the ceiling junction box infrastructure. A fire alarm control module supplies one-hundred-twenty-volt power and connects via a one-inch conduit to the door controller cabinet.
ADO PUSH PLATE (EXTERIOR) KEY PAD, SURFACE MOUNTED ONTHE UNSECURE SIDE. (EXTERIOR) 3/4" C. 3/4" C. 3/4" C. 8"X8"X6" SQ JUNCTION BOX. MOUNT JUNCTION BOX ABOVE DOOR IN THE CEILING SPACE OF THE SECURE SIDE AUTOMATIC DOOR OPERATOR ADO PUSH PLATE (IN VESTIBULE) KEY PAD, SURFACE MOUNTED ON THE UNSECURE SIDE. (IN VESTIBULE) 3/4" C. 3/4" C. 3/4" C. AUTOMATIC DOOR OPERATOR 8"X8"X6" SQ JUNCTION BOX. MOUNT JUNCTION BOX ABOVE DOOR IN THE CEILING SPACE OF THE SECURE SIDE FIRE ALARM CONTROL MODULE Z 120V PWR 3/4" C. 1" CONDUIT TO DOOR CONTROLLER CABINET ADO PUSH PLATE (INTERIOR) 3/4" C. 3/4" C. D