An eight-inch by eight-inch by six-inch square junction box is mounted above the door within the ceiling space on the secure side, receiving one hundred twenty volt emergency power. A three-quarter-inch conduit connects the door latch power supply to the junction box, with a one-inch conduit routing to the door controller cabinet. A surface-mounted proximity card reader is positioned on the unsecure side at forty-two inches above finished floor. Electric panic hardware connects via power transfer to complete the access control circuit.
3/4" C. DOOR LATCH POWER SUPPLY 8"X8"X6" SQ JUNCTION BOX. MOUNT JUNCTION BOX ABOVE DOOR IN THE CEILING SPACE OF THE SECURE SIDE 1' CONDUIT TO DOOR CONTROLLER CABINET +42" A.F.F. PROXIMITY CARD READER, SURFACE MOUNTED ON THE UNSECURE SIDE. POWER TRANSFER ELECTRIC PANIC HARDWARE 120V EM POWER