A 1-hour shaftwall assembly designated as UL-U469 features a hollow structural section steel tube surrounded by 1-inch gypsum shaft liner and 1-layer of 5/8-inch gypsum board on 2-1/2-inch steel jamb struts. The assembly incorporates 1-1/2-inch by 1-1/2-inch 20-gauge minimum clips secured with 1-inch shaft liner, with fasteners spaced at 24 inches on center. J-runners receive a continuous bed of sealant at partition junctions, and spray-applied fireproofing is applied to structural steel elements on the elevator shaft side.
1" GYPSUM LINER PANEL FASTENERS AT 24" OC J RUNNER J RUNNER 1" GYPSUM LINER PANEL PARTITION AS SCHEDULED BED OF SEALANT SPRAY APPLIED FIREPROOFING PARTITION AS SCHEDULED ELEVATOR SHAFT SIDE HSS TUBE - REFER TO STRUCTURAL 1" SHAFT LINER 5/8" 1" 8" 8 5/8" 1 1/2" X 1 1/2" 20 GA MIN CLIPS WITH 1" SHAFT LINER UL -U469 1 HOUR SHAFTWALL ASSEMBLY WITH 1 LAYER OF 5/8" GYP BD ON 2 1/2" STL JAMB STRUTS WITH 1" SHAFT LINER FIRE PROTECTION DETAIL AT