A typical elevator door frame installation within a rated wall partition features a two-hour partition shown and a one-hour partition simulated. The framing utilizes two-and-a-half-inch by sixteen-gauge steel studs with coreboard fillers and sixteen-gauge by five-inch steel bent shapes at the top and bottom of the box insert, sized to fit. A cut-out is provided for recess installation at the CMU wall with wire-opening coordination and a conduit connection on the hoistway side. A braille plate and hall lantern or hall call buttons are integrated into the frame assembly.
2" TYP. ELEVATOR DOOR FRAME W/ BRAILLE PLATE HALL LANTERN / HALL CALL BUTTONS, TYP. 1/2" TYP. DIM. PT. SEE FLOOR PLAN 2 1/2" X 16 GA. STEEL STUD COREBOARD FILLER B SECTION 'B' 16 GA. X 5" STL. BENT SHAPE TOP AND BOTTOM OF BOX INSERT SIZE TO FIT 2" TYP. (2 HR. PTN. SHOWN, 1 HR. PTN. SIM.) PROVIDE CUT-OUT FOR RECESS INSTALLATION AT CMU WALL, W.O. COORDINATION CONDUIT CONNECTION ON THE HOISTWAY SIDE, TYP.