The detail illustrates a 3-inch precast concrete cap featuring a 3/8-inch reveal, secured to the top of an 8-inch reinforced ground-face concrete masonry unit (CMU) wall. The connection is made using core-drilled pin with a number 3 reinforcing bar and epoxy embedded 4 inches below the cap and 1 1/2 inches within the seat, with two reinforcing bars at each segment. A sealant and backing rod are specified in the horizontal joint beneath the cap, and the CMU wall includes two number 4 reinforcing bars at 32 inches on center with alternate hooks.
Text on the drawing
8" REINFORCED GROUND FACE CMU 3" PRECAST CONCRETE CAP WITH 3/8" REVEAL. CORE DRILL. PIN W/ #3 REBAR AND EPOXY 4" BELOW CAP, 1 1/2" WITHIN SEAT. (2) REBAR AT EACH SEGMENT. SEALANT AND BACKING ROD (2) #4 @32" O.C. ALTERNATE HOOKS
Members view this detail in full resolution, download the CAD files (SVG, PDF), and open any detail in the built-in CAD editor to edit and export DXF or DWG.