Text on the drawing
STEEL STUD GWB PRIMARY LAYERS EXTEND TO STRUCT. 4 7/8" @ 3 5/8" STUDS 5 1/4" @ 4" STUDS 7 1/4" @ 6" STUDS SOUND ATTENUATION BLANKET S2A FIRE RATING NOTE: @ 1HR RATED LOCATIONS, ASSEMBLY SHALL CONFORM TO GA FILE NO. WP 1072. WALL TAG IS PLACED IN PLAN ON SIDE OF WALL