This plan detail shows an exterior wall assembly transitioning from a six-inch concrete stem wall to an interior finish layer. A two-and-a-half-inch metal furring stud is positioned against the concrete wall, aligning with the plane of the interior six-inch metal stud face above. Five-eighths-inch gypsum board with a painted finish is attached to the furring. A dashed reference line indicates the back of the insulation panel located above.
2 1/2" METAL FURRING STUD PLANE OF INTERIOR 6" METAL STUD FACE ABOVE TO ALIGN INTERIOR 6" CONCRETE STEM WALL LINE INDICATES BACK OF INSUL. PANEL ABOVE 5/8" GYP. BD., PAINT TYP SEE FINISH SCHEDULE 2 1/2" 3 1/2" 2 1/2" 5/8" 6"
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.