A fire and security door assembly is integrated with a wall opening and a conveyor system above the floor. A flared side guard is required on both sides of the opening with a minimum 36-inch bag clearance. Floor supports are omitted from the view, and a safe off area is located below the top of the bed with a dimensioned width of 3 feet 3 inches. The door rails mount adjacent to the wall and frame opening extending above the finished floor level.
BG 3'-3" 9" MIN. WALL SECURITY DOOR 36" BAG CLEAR T.O.B. A.F.F. FLOOR SUPPORTS NOT SHOWN FLARED SIDE GUARD REQUIRED BOTH SIDES WALL FLOOR DOOR RAILS DOOR RAILS FIRE/SECURITY DOOR 36" BAG CLEAR (MINIMUM) T.O.B. A.F.F. A/R CONVEYOR SIDE GUARD TO WALL OPENING FLOOR SUPPORTS NOT SHOWN SAFE OFF AREA BELOW TOP OF BED