This assembly details a roof screen wall featuring .040-inch aluminum Kynar-coated Morin X-12 corrugated horizontal metal panels secured over tube steel supports and auxiliary metal stud framing. The top of the assembly is capped with a painted galvanized sheet metal flashing. Closure flashings are integrated at the steel posts and secured with number 10 by 1-inch wafer head screws spaced at 24 inches on center.
PARAPET OFFICE 113' - 0" ROOF SCREEN 123' - 0" PAINTED GALVANIZED SHEET METAL FLASHING TUBE STEEL SUPPORT. INFILL WITH METAL STUD FRAMING AS NEEDED .040 ALUMINUM KYNAR COATED MORIN X-12 CORRUGATED HORIZONTAL PANEL SYSTEM (MTL-3) FLASHING AT STEEL POSTS 3' - 0" .040 ALUMINUM KYNAR COATED CLOSURE FLASHING #10x1" WAFER HEAD SCREW 24" O.C. 2 2