A hollow structural section tube integrates within a UL-U469 one-hour rated shaft wall assembly. The assembly incorporates two four-inch steel studs, one-inch gypsum shaft liner panels, and five-eighths inch gypsum board secured with twenty-gauge minimum clips. J-runners frame the perimeter with fasteners spaced at twenty-four inches on center over a bed of sealant. The steel tube anchors to an embed or post-applied steel base plate with spray-applied fireproofing.
1" GYPSUM LINER PANEL FASTENERS AT 24" OC J RUNNER J RUNNER 1" GYPSUM LINER PANEL PARTITION AS SCHEDULED BED OF SEALANT SPRAY APPLIED FIREPROOFING PARTITION AS SCHEDULED ELEVATOR SHAFT SIDE HSS TUBE - REFER TO STRUCTURAL 1" SHAFT LINER 5/8" 1" 8" 8 5/8" 1 1/2" X 1 1/2" 20 GA MIN CLIPS WITH 1" SHAFT LINER UL -U469 1 HOUR SHAFTWALL ASSEMBLY WITH 1 LAYER OF 5/8" GYP BD ON 2 1/2" STL JAMB STRUTS WITH 1" SHAFT LINER UL -U469 1 HOUR SHAFTWALL ASSEMBLY - (2) 4" STUDS EMBED OR POST APPLIED STEEL BASEPLATE - REFERENCE STRUCTURAL FIRE PROTECTION DETAIL AT