This curtain wall head assembly integrates a steel support structure with a metal panel cladding system and vision glass below. The horizontal mullion features a pressure cap and secures to the overhead structure. A deluge system supply pipe is mounted behind the assembly and connects to a fire protection sprinkler head positioned one foot away. The steel curtain wall support coordinates with structural steel and fire protection requirements per the reflected ceiling plan.
CLOSURE TO MATCH CW-2 STEEL CURTAIN WALL SUPPORT, RE: STRUCT. WIND LOAD CONNECTION TO SUPPORT STEEL DELUGE SYSTEM HEAD PIPING HORIZ MULLION WITH PRESSURE CAP METAL PANEL ASSEMBLY VISION GLASS 1'-0" MCP-1, PER RCP DELUGE SYSTEM SUPPLY, RE: FIRE PROTECTION