Accessibility dimensions are provided for accessible plumbing fixtures including drinking fountains, lavatories, and urinals. The drinking fountain details specify standing and accessible heights ranging from 36 inches maximum to 38 to 43 inches, with a 15-inch minimum spout reach. Lavatory clearances require a 27-inch minimum knee clearance height, a 34-inch maximum rim height, and pipe insulation for drain lines per ADA guidelines. Urinal installation requirements specify a 17-inch maximum rim height and a 60-inch minimum vertical clearance for privacy screens.
URINAL LAVATORY KNEE/TOE CLEARANCE DRINKING FOUNTAIN D B C URINAL SCREEN HC URINAL W/ ENLONGATED RIM MIRROR HC LAVATORY PROVIDE INSULATION FOR DRAIN PIPE AT HC LAV PER ADA BOTTOM OF MIRROR A PLAN: LAVATORY CLEAR FLOOR SPACE MIN 18" MAX 17" MIN 60" MIN 48" MAX 40" CLR 9" CLR 27" MAX 34" 8" MIN CLR 28" MAX 5" MIN 15" MAX 36" 30" EQ EQ 38"- 43" ACCESSIBLE FOUNTAIN STANDING FOUNTAIN MIN 6" 11" MIN 12" MAX MIN 6"