A quarter-inch by ten-inch steel stair stringer terminates adjacent to a half-inch face-of-partition assembly. A joint filled with a backing rod and sealant is provided in the half-inch gap between the stringer and the partition wall.
1/2" F.O. PARTITION AS SCHELD 1/4X10 STAIR STRINGER SEALANT & BACKER