This assembly details the installation of a main roof drain and an adjacent overflow roof drain within a roof system. The roof assembly features tapered insulation sloped at one-half inch per foot, transitioning to a sump pan for metal decks. The drain bowls are secured to the roof opening framing with deck clamps and receiver pans. The roofing membrane is extended into the drain bowl and bedded in sealant, with vapor retarders sealed to the drain bowl flange. Drain extension rings are utilized to accommodate the total thickness of the roofing system, topped with drain strainers, including an overflow collar for the secondary drain. Drainage piping is coordinated with plumbing drawings, and spray foam insulation is applied at the perimeter of the drain assembly.
Text on the drawing
SUMP PAN FOR METAL DECKS ONLY AREA OF TAPERED INSULATION AT 1/2" PER FOOT DECK CLAMP RECEIVER PAN ROOF OPENING FRAMING - REFER TO STRUCT DRAINAGE PIPES, SEE PLUMBING DRAWINGS MAIN ROOF DRAIN 2' - 6" 3' - 0" MINIMUM 2' - 6" 1/2" PER FOOT SLOPE 1/4" PER FOOT SLOPE OVERFLOW ROOF DRAIN DRAIN STRAINER WITH OVERFLOW COLLAR SEALANT, TYPICAL DRAIN EXTENSION RINGS TO ACCOMMODATE ROOFING SYSTEM THICKNESS - REFER TO PLUMBING - TYP ROOF SYSTEM ASSEMBLY SPRAY FOAM INSULATION - TYP SEAL VAPOR RETARDER TO DRAIN BOWL FLANGE, TYPICAL DRAIN BOWL EXTEND MEMBRANE INTO DRAIN AND BED SEAL MEMBRANE TO DRAIN EXTENSION RING- TYP 1/4" PER FOOT SLOPE 1/2" PER FOOT SLOPE DRAIN STRAINER 1' - 0" 1' - 0" 1' - 0" 1' - 0" PER ROOF ASSEMBLY ON SHEET A2.1.6 NOT FOR CONSTRUCTION SEALS AND SIGNATURES 100% DESIGN DEVELOPMENT