Cold-formed steel studs terminate below a concrete mezzanine slab on metal decking with an intervening metal stud track. A one-half-inch maximum gap between the top of the gypsum board and studs and the bottom of the deck contains a UL-listed fire stop. Mineral wool insulation fills the cavity between the metal studs. Gypsum board clads the stud wall faces.
1/2" GAP MAX SECT A-A CONCRETE MEZZANINE SLAB METAL DECKING OPEN-WEB JOIST 2X METAL STUD TRACK STUD WALL GYP BOARD CONCRETE MEZZANINE SLAB METAL DECKING 2X METAL STUD TRACK STUD WALL GYP BOARD 2X METAL STUD MINERAL WOOL INSULATION U.L. LISTED FIRE STOP IN 1/2" GAP A & STUDS B.O. DECK T.O. GYP U.L. LISTED FIRE STOP IN 1/2" GAP 2X METAL STUD