A pre-finished metal frame at a corridor door opening is installed within a gypsum board partition on metal stud framing. Wood trim is attached to the gypsum board and resilient channels without contacting the metal framing. Joint sealant with a backer rod is specified around the frame perimeter per the joint sealant schedule. The door leaf is scheduled separately, and dimensions indicate a zero and one-half inch clearance alongside zero and one-quarter inch reveals.
SEE ASSEMBLIES UNIT SIDE / ROOM SIDE CORRIDOR DOOR OPENING 08 12 14 - PRE-FINISHED METAL FRAME DOOR, SEE SCHEDULE 07 92 00 - JOINT SEALANT AND BACKER ROD SEE ASSEMBLIES DOOR OPENING 0' - 1 1/2" 0' - 0 1/4" DOOR, SEE SCHEDULE 07 92 00 - JOINT SEALANT AND BACKER ROD 08 12 14 - PRE-FINISHED METAL FRAME 08 12 14 - TRIM 0' - 1 1/2" 0' - 0 1/4" 06 20 00 - WOOD TRIM ATTACH TO GB AND RESILIENT CHANNELS WITHOUT CONTACTING METAL FRAMING 06 20 00 - WOOD TRIM ATTACH TO GB AND RESILIENT CHANNELS WITHOUT CONTACTING METAL FRAMING 08 12 14 - TRIM