A wall-mounted handrail features a 38mm diameter steel pipe handrail with a 90-degree return to the wall complete with a rounded end cap at all terminations. The railing supplier provides supports spaced at a maximum of 1200mm on center. Solid blocking is provided within the wall for the secure connection of supports where required. The handrail is positioned at a height of 2 feet 10 inches to 3 feet 2 inches per code requirements relative to the edge of the stair nosing.
RETURN RAILING 90° TO WALL c/w ROUNDED END CAP at ALL TERMINATIONS RAILING SUPPLIER TO PROVIDE SUPPORTS at 1200mm (4'-0") O.C. MAXIMUM EDGE OF STAIR NOSING OF FIRST STAIR RISE LINE OF STAIRS -REFER TO STAIR SECTIONS FOR RELATED DETAILS 38mm (1-1/2") ⌀ STEEL PIPE HANDRAIL 1'-0" 2'-10" to 3'-2" 865 to 965mm (PER BCBC 2018) at END 1'-2" PROVIDE SOLID BLOCKING IN WALL FOR CONNECTION OF SUPPORTS WHERE REQUIRED TYP. 3'-0" 6" 3'-0" PROVIDE 6mm (1/4") CLOSURE PLATE at STRINGER -PAINTED -TYPICAL TYPICAL STRINGER, TREAD & STRINGER CONSTRUCTION - REFER TO STRUCTURAL 2"x1" HORIZONTAL FLAT BAR - TOP RAIL 2"x1/2" VERTICAL FLAT BAR SUPPORTS at 1200mm (4'-0") O.C. MAX 3/4"x1/2" VERTICAL FLAT BAR at 100mm (4") O.C. MAX INTERMEDIATE BALUSTERS 100mm (4") MAX A70.01 2 100mm (4") MAX STAIR NOSING LINE 1" 4" 2"x1" HORIZONTAL FLAT BAR - BOTTOM RAIL STRINGER -REFER TO STRUCTURAL STAIR TREAD 2"x1" HORIZONTAL FLAT BAR - TOP RAIL 2"x1/2" VERTICAL FLAT BAR SUPPORTS at 1200mm (4'-0") O.C. MAX 3/4"x1/2" VERTICAL FLAT BAR at 100mm (4") O.C. MAX INTERMEDIATE BALUSTERS CONNECTION -REFER TO STRUCTURAL 42"