An MC12x10.6 channel stair stringer rests on a concrete slab on grade and is anchored with a three-quarter-inch diameter expansion bolt through an L 3x3x5/16 by six-inch angle welded with a quarter-inch fillet weld. A steel column supports a C12x20.7 member via a three-eighths by three-and-a-half by three-and-a-half-inch cap plate welded with quarter-inch fillet welds. A C12x20.7 ledger channel for the stair landing is secured to a concrete tilt-up wall using a three-eighths by three-and-a-half by nine-inch plate with three three-quarter-inch diameter A-325 N bolts and three-quarter-inch diameter by five-inch Simpson Titen HD anchors at framing members plus one at eighteen inches on center.
MC12x10.6 OR EQUAL STAIR STRINGER L 3x3x5/16 x 6" SLAB ON GRADE SEE PLAN 3/4" DIA EXPANSION BOLT 1/4 NOTE: ACTUAL STAIRS TO BE PRE- ENGINEERED BY STEEL FABRICATOR. PROVIDE SHOP DRAWINGS FOR REVIEW. 1/4 1/4 3/8"x3-1/2"x3-1/2 " CAP PLATE STEEL COLUMN C12X20.7 1/4 NOTE: STAIR LANDING SUPPORT COLUMNS MAY BE CONTINUOUS FOR THIS OPTION FRAME LANDING BEAMS INTO COLUMN WITH SHEER TAB (6/S0.2) AND CONNECT COLUMN TO EACH FLOOR BEAM (WEB) WITH CLIP ANGLES 8" LONG (L8X4X7/16 EACH SIDE OF COLUMN TYPICAL) C12x20.7 LEDGER FOR STAIR LANDING 3/4" DIA. x 5" SIMPSON TITEN HD ANCHORS @ FRAMING MEMBERS AND (1) 3/4" DIA. TITEN AT 18" O.C. CONCRETE TILT UP WALL, SEE PLANS 3/8"x3-1/2"x9" PLATE w/ (3) 3/4" DIA. A-325 N BOLTS 5/16 TYP.