A tilt-up concrete panel features a clear penetrating sealer on the exterior surface. Vertical joints between panels utilize a closed-cell neoprene compressible filler, backer rod, and sealant. The roof membrane slopes toward the scupper opening, which incorporates a two-inch dam behind the overflow scupper. A six-inch by six-inch prefinished downspout integrates into the drainage path. The overflow scupper sits at the same elevation as the primary scupper, with additional reference provided to detail 5/A-60010.
Text on the drawing
# X TILT-UP CONCRETE PANEL WITH CLEAR PENETRATING SEALER ON EXTERIOR SURFACE. BACKER ROD AND SEALANT SEALANT CLOSED CELL NEOPRENE COMPRESSIBLE FILLER ROOF MEMBRANE 6" X 6" PREFINISHED DOWNSPOUT SLOPE FACE OF PILASTER ROOF MEMBRANE SLOPE PER PLAN 1' - 0" +/- A-A OVERFLOW SCUPPER, INSTALLED AT SAME ELEVATION AS PRIMARY SCUPPER WITH 2" DAM BEHIND SCUPPER OPENING AT OVERFLOW, SEE DETAIL 5/A-60010 06 A-60010 03 A-60010 2' - 6" 2' - 9 1/2" SLOPE SLOPE A-60010 05