A vertical hanger wire connects to the bottom flange of a structural steel member through a 12 gauge by 3/4 inch minimum ceiling clip secured with a 1/2 inch machine bolt. The vertical wire is secured with three tight turns in 1-1/2 inches and subjected to load testing per IR 25-2.13. A seismic bracing wire connects to the top flange of the steel member using a 1-inch wide by 12 gauge minimum steel strap bent to align with the wire. The bracing wire is finished with four tight turns in 1-1/2 inches and also tested per IR 25-2.13.
(A) AT STEEL BEAMS STRUCTURAL STEEL MEMBER CEILING CLIP 12 GA. X 3/4" WIDE (MIN.) 1/2" MACHINE BOLT (3) TIGHT TURNS IN 1-1/2" VERTICAL HANGER WIRE LOAD TEST PER IR 25-2.13 LOAD TEST PER IR 25-2.13 STEEL STRAP 1" WIDE X 12 GA. (MIN.), BEND TO ALIGN WITH WIRE (4) TIGHT TURNS IN 1-1/2" BRACING WIRE, SEE IR 25-2.13