Suspended acoustical ceiling system featuring acoustical panels supported by main runners and cross runners hung with hanger wires. A 1"x2" perimeter edge trim terminates the ceiling system typically at the gypsum board soffit transition. The gypsum board soffit and suspended ceiling elevations are set by the exterior window elevation. Structural framing requirements and building envelope details are coordinated per structural and envelope sheets.
HANGER WIRE. CROSS RUNNER MAIN RUNNER ACOUSTICAL PANEL 1"X2" PERIMETER EDGE TRIM, TYP., OR APPROVED EQUAL SEE SHEETS A9.30 & A9.31 FOR CEILING ATTACHMENT DETAILS WHERE EXTERIOR WINDOW OCCURS IN ROOM THE ELEVATION OF GYP BD SOFFIT AND SUSPENDED CEILING ARE SET BY EXTERIOR WINDOW ELEVATION. SEE DETAIL SEE A8.2x SERIES SHEETS FOR BUILDING ENVELOPE DETAILS ALIGN ALIGN 6" SEE STRUCTURAL DRAWINGS FOR FRAMING REQUIREMENTS