An acoustic tile ceiling suspension system is suspended from the structure above using wire hangers and ceiling clips. The metal suspension system main runner is tied back with forty-five degree splay wires secured four ways to the structure above for seismic bracing. A vertical bracing strut is spaced at twelve feet zero inches on center. The bottom of the ceiling height is coordinated per the reflected ceiling plan.
ACOUSTIC TILE CEILING METAL SUSPENSION SYSTEM, MAIN RUNNER 45 DEGREE SPLAY WIRE SECURED TO STRUCTURE (4 WAYS) VERTICAL BRACING STRUT @ 12' - 0" O.C. WIRE HANGER CEILING CLIP STRUCTURE ABOVE B.O. CEILING SEE RCP B.O. CEILING SEE RCP
Members view this detail in full resolution, download the CAD files (SVG, PDF), and can adapt it in the built-in CAD editor — export DXF, DWG, or PDF.
Start membership