A one-hour fire-resistant smoke barrier head-of-wall assembly occurs beneath a concrete floor or roof slab over a non-rated fluted steel deck oriented perpendicularly or diagonally to the flutes. A continuous twenty-two gauge minimum three-inch deep-leg deflection track attaches to the overhead deck at a maximum spacing of twelve inches on center. Gypsum board and studs remain unattached to the deflection track within the designated slip area, leaving a three-quarter-inch clearance gap. A continuous two-inch wide by twenty-two gauge metal strap provides top attachment of the studs one inch below the track boundary. A scheduled ceiling line intersects the stud framing below the strap attachment.
ONE HOUR FIRE RESISTANT AND ONE HOUR FIRE RESISTANT SMOKE BARRIER UL-HW-D-0108 CONCRETE FLOOR OR ROOF SLAB NOTE: REFER TO UL LISTING FOR COMPLETE ASSEMBLY REQUIREMENTS 1" _ NON-RATED FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF PERPENDICULAR OR DIAGONAL TO FLUTES LINE OF CEILING AS SCHEDULED CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS CONT 22 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAX DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA 3/4"